Borri UPS Servicing, Battery Replacements and Overhauls
5 Year Servicing, AC and DC Capacitor Replacements and Battery Replacement
Our Experienced UPS Engineers
Our engineers are located throughout the UK and are fully trained on the Borri UPS products. Our engineers have access to any technical documentation associated with any Borri UPS system.
Borri UPS Replacement
Should your Borri UPS be end of life and repairs are no longer an option, we can arrange to visit site and perform a comprehensive survey assessing the current infrastructure, load requirements and UPS environment enabling us to suggest suitable replacement UPS options offering both improved reliability and efficiency savings on current operations.
Borri UPS Battery Replacement
UPS Power Services can supply, install, maintain or replace a wide variety of batteries, the most common being sealed lead acid (VRLA) with a 5 or 10 year design life.
Borri UPS Repairs, Spares and Replacements
UPS Repair / Replacement on All Borri UPS Models and Sizes
UPS Power Services have a UK stock of UPS available for immediate despatch to site in an emergency situation often within four hours of the fault occurring.
Spares are readily available in the UK for quick and efficient dispatch to site often supplying replacement modules in the case of the Modular UPS ranges and onsite repairs for the standalone UPS.
Our team of on call electrical engineers and electricians can deliver, position and electrically install and commission the UPS on any site across the UK.
This combination of knowledgeable, experienced and trained personnel with the availability of spares on hand with the Borri UPS products enables us to deliver the very best support to our clients.
Get Technical Support


Borri B8000FXS/B8031FXS/B8033FXS 10k-20kVA


Borri B9000FXS 60-300kVA UPS System


Borri B9600FXS UPS 400-800kVA UPS System


Borri Ingenio Compact 10-20kVA, 3/3 UPS System


Borri Ingenio Plus 30-160kVA, 3/3 UPS System
Why is it important to change Capacitors?
Capacitors, like batteries degrade over time. When a capacitor fails, you may not see any visible effects but if one capacitor fails, the others may have to work overtime, which in effect reduces the overall life of all the capacitors.
The rate of degradation of a capacitor is governed by many things, however, the operating temperature and the capacity usage percentage will have the greatest effects.
Capacitors operating towards the high end of their voltage rating will degrade faster than if the same capacitor is operating at half of its nominal voltage rating.
In many cases a capacitor that fails may encourage the UPS to switch to bypass, putting the load in danger. To maximise the performance of your UPS, ensure you take care of these components and aim to change them at or near their rated lifespan of between 5 and 7 years.
UPS Power Services can diagnose the problem early and our engineers can replace part or all of the capacitor banks to ensure maximum performance. A UPS operating at over 80% loading will usually require replacement components sooner than one operating at 75% and under.
Why is it important to change Cooling Fans?
The Fans inside a UPS are some of the hardest working components, they are constantly running to cool the UPS 24 hours a day, 7 days a week. The fans installed in Borri UPS are of a very high grade in order to endure the life cycle of a loaded UPS. Like any item that has moving parts they will have a design life, as parts of the items will wear and eventually start to breakdown. The Borri fans have a design life of around 40,000 hours, if running 24/7 that is just under 5 years. If not replaced they will start to fail and once the UPS is not being cooled lots of items in the UPS will start to very rapidly fail, causing more damage to non-replaceable components eventually causing a UPS failure. Preventative maintenance will recommend these are changed every 5 years mitigating this risk.
Borri UPS Overhauls and 5 Year Servicing
It is critical to ensure that all internal components including UPS batteries, capacitors and fans are all routinely serviced and replaced when required.
When a Borri UPS has been actively in service for a period of five years, a number of components will need changing to ensure the UPS keeps operating within normal limits for it’s entire working life.
The components that generally require changing are;
- AC Capacitors
- DC Capacitors
- Cooling Fans
- Batteries
The Borri design has been carefully thought out to ensure this service can be completed in a relatively short time period and easily undertaken by one of our trained engineers.
Our engineers are able to perform these works at any time of the day or night to suit your requirements and can be done as part of the annual service visit if required.
You don’t need a service contract or agreement in place to have these works carried out. We can provide a quotation for all works including battery replacements and can offer options for service contracts or annual maintenance if required.
Request a Quote
Borri UPS Battery Replacement
The batteries are critical to the integrity of your UPS system. Most modern UPS systems will perform and monitor short battery tests on a regular basis, however it is also essential to maintain these systems to ensure they will operate correctly when needed.
UPS Power Services can supply, install, maintain or replace a wide variety of batteries, the most common being sealed lead acid (VRLA) with a 5 or 10 year design life.


Approved Yuasa UPS Battery Partner
UPS Power Services are an approved Yuasa Battery Partner. This means we have direct access to extensive Yuasa battery stock located in the UK, full technical support from our trained UPS specialists and are supported by Yuasa battery application engineers.
UPS Power Services and Yuasa battery engineers are equipped for onsite specification, sizing, technical quotations, full electrical installation and after sales support and testing.
Yuasa batteries set the industry benchmark for UPS batteries in the UK and globally for over 30 years. The reason is simple – premium quality, unmatched reliability, long life and advanced engineering with years of application expertise.

Borri UPS Service & Maintenance
An uninterruptible power supply is a crucial piece of equipment. It’s essential that you can rely on it to provide critical power protection at all times. But wear and tear over time is inevitable, and without regular check-ups a UPS’s performance can easily become compromised, increasing the likelihood of failure and downtime.Our specialist UPS Health Checks give you the peace of mind that your units are running at peak performance and optimum efficiency.
What’s Included In A Borri UPS Health Check?
- Visual test: thorough inspection of the installed UPS system / battery set
- Physical tests: review of all electrical connections. Thermal imaging included as standard to detect the hardest-to-find heat-related issues
- Mechanical tests: functional checks including recording electrical measurements and the system’s operational state
- Environmental tests: check the surroundings for possible problems such as dust or humidity
- Download and comprehensive review of the UPS history logs
- Firmware upgrades
- Full reporting of any faults found during the PMV
- Our recommendations to improve operational reliability
Do You Need Help?
Please get In touch to discuss anything Borri UPS or Non-Borri UPS related. Our Technical Engineers can help guide you through any UPS replacement, design or installation query you my have. We have battery stock available for urgent deliveries and engineers on standby at short notice. Please call us on 0800 112 3654.
Borri UPS Service & Maintenance Plans
UPS system maintenance and service contracts for all makes and models of UPS with quick site response, parts and
travel included along with sophisticated site reporting and service tracking for your entire asset list.
Service Plan One
9am-5pm Onsite
Onsite response 12Hr
Tech support – 24/7
Freephone call out
One onsite service/Yr
Travel – Included
Labour – Included
Service Plan Two
24/7 Onsite Cover
Onsite reponse 8Hr
Tech support – 24/7
Freephone call out
One onsite service/Yr
Travel – Included
Labour – Included
Service Plan Three
24/7 Onsite Cover
Onsite response 4Hr
Tech support – 24/7
Freephone call out
One onsite service/Yr
Travel – Included
Labour – Included
Bespoke Servicing
Cover time – Bespoke
Bespoke response
Bespoke Support
Freephone call out
Bespoke services/Yr
Travel – Bespoke
Labour – Bespoke
TESTIMONIALS
WHAT OUR CUSTOMERS SAY

Bringing together some of the industry’s most experienced and talented people, we are committed to improving standards across the emergency power landscape through reliable and efficient delivery of all our services.
Get in Touch With Us
Contact Info
Visit Us
Sheffield Road, Chesterfield, S41 9ED